Compliance Standards
1. ASTM D3578-00a
2. EN 455 Part 1 & 2
3. AS 4011-1997
4. MIL STD 105E (SAMPLING PLAN)
The gloves shall be sampled and tested
accordingly to comfirm to the follwing
quality level:
ASTM D3578-00a Standards AS 4011 - 1997 Standards (EN455 1 & 2)
DefectsInsp. LevelAQLDefectsInsp. LevelAQL
1) Watertight Test
2) Major Defects
3) Minor Defects
4) Dimensions
5) Physical Properties
G1
G1
G1
S2
S2
2.5
2.5
4.0
4.0
4.0
 1) Watertight Test
2) Major Defects
3) Minor Defects
4) Dimensions
5) Physical Properties
G1
G1
G1
S2
S2
2.5
2.5
4.0
4.0
4.0
Weight
Extra Small5.8 grams +/- 0.5
Small6.2 grams +/- 0.2g
Medium6.8 grams +/- 0.2g
Large7.2 grams +/- 0.2g
Extra Large7.6 grams +/- 0.2g
Thickness (double wall)
at Cuffmin. 0.11mm +/- 0.02mm
at Palmmin. 0.16mm +/- 0.02mm
at Finger Tipmin. 0.18mm +/- 0.02mm
Physical Properties
TensileElongation
Before Aging18 M. P. A.650%
After Aging9 M. P. A.500%
 
Width by Size
Extra Small73mm +/- 2mm
Small85mm +/- 2mm
Medium95mm +/- 2mm
Large108mm +/- 2mm
Extra Large113mm +/- 2mm
Length
 240mm +/- 3mm
(from finger tip to beading at cuff)
Protein Content
 < 50 ug/g


On Line Chlorinated Powder Free and Off Line Polymer